29.120.50 - Fuses and other overcurrent protection devices
Fuses and other overcurrent protection devices
Sicherungen. Uberstromschutzvorrichtungen
Coupe-circuits a fusibles et autres dispositifs de protection contre les surintensites
Varovalke in druga nadtokovna zaščita
General Information
- Technical report16 pagesEnglish language
sale 15% off
IEC 62873-3-1:2020 is available as IEC 62873-3-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62873-3-1:2020 applies to devices equipped with screwless-type terminals for current not exceeding 40 A, primarily suitable for connecting unprepared copper conductors of cross‑section up to 10 mm2. This second edition cancels and replaces the first edition published in 2016. This edition con...view more
- Standard15 pagesEnglish language
sale 15% off
IEC 62873-3-2:2020 is available as IEC 62873-3-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62873-3-2:2020 applies to devices equipped with flat quick-connect terminations consisting of a male tab with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rat...view more
- Standard13 pagesEnglish language
sale 15% off
This part of IEC 60282 applies to all types of high-voltage current-limiting fuses designed for
use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated
voltages exceeding 1 000 V.
- Standard82 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft73 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 60282 applies to expulsion fuses complying with IEC 60282-2 and specifies
additional testing requirements for fuses employing a cutout fuse-base that utilizes polymeric
insulators.
- Standard19 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft15 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard13 pagesEnglish and French language
sale 15% off
- Amendment8 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment6 pagesEnglish language
sale 10% off- e-Library read for1 day
2020-01-09: TC 23E requests BT to decouple the EN from the EMC Directive and publish the standard without delay - to offer for LVD: partial compliance but all remarks have been implemented.
2019-10-01: CLC/TC 23E and CLC/TC 210 to coordinate to address the statistical methods.
- Amendment23 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard21 pagesEnglish and French language
sale 15% off
This part of IEC 61643 specifies standard test circuits and methods for thyristor surge
suppressor (TSS) components. These surge protective components, SPCs, are specially
formulated thyristors designed to limit overvoltages and divert surge currents by clamping and
switching actions. These SPCs are used in the construction of surge protective devices
(SPDs) and equipment used in Information & Communications Technologies (ICT) networks
with voltages up to AC 1 000 V and DC 1 500 V. This doc...view more
- Standard79 pagesEnglish language
sale 10% off- e-Library read for1 day
This document describes the principles for selection, installation and coordination of SPDs intended for use in Photovoltaic (PV) systems up to 1500 V DC and for the AC side of the PV system rated up to 1000 V rms 50/60 Hz.
The photovoltaic installation extends from a PV array or a set of interconnected PV-modules to include the associated cabling and protective devices and the converter up to the connection point in the distribution board or the utility supply point.
This document considers S...view more
- Technical specification44 pagesEnglish language
sale 10% off- e-Library read for1 day
In addition to the general requirements of IEC 60077-2, this part of IEC 60077 gives rules for
AC circuit-breakers, the main contacts of which are connected to AC overhead contact lines;
the nominal voltage of these circuits being in accordance with IEC 60850.
This document, together with IEC 60077-2, states specifically:
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers comply with reference to:
– operation and behaviour in normal servic...view more
- Standard33 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard6 pagesEnglish language
sale 15% off
- Amendment6 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
In addition to the general requirements of NEN-EN-IEC 60077-2, NEN-EN-IEC 60077-3 gives the rules for circuit-breakers, the main contacts of which are connected to DC power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V DC according to IEC 60850. This part of IEC 60077, together with IEC 60077-2, states specifically: a) the characteristics of the circuit-breakers; b) the service conditions with which circuit-breakers complies with reference to: - operati...view more
- Standard32 pagesEnglish language
sale 10% off- e-Library read for1 day
The purpose of NEN-EN-IEC 60077-5 is to give additional or amended rules for high voltage (HV) fuses as a supplement to those given by IEC 60077-2. The high voltage fuses concerned are those connected into power and/or auxiliary circuits. The nominal voltage of these circuits lies between 600 V DC and 3 000 V DC, according to IEC 60850. These fuses can also be used in auxiliary AC circuits up to a nominal voltage of 1500 V. This document together with IEC 60077-2 states specifically: a) the char...view more
- Standard32 pagesEnglish language
sale 10% off- e-Library read for1 day
EN-IEC 61643-331 is a test specification for metal oxide varistors (MOV), which are usedfor applications up to 1 000 V AC or 1 500 V DC in power lines, or telecommunication, orsignalling circuits. They are designed to protect apparatus or personnel, or both, from hightransient voltages.This document applies to MOVs having two electrodes and hybrid surge protectioncomponents. This document also does not apply to mountings and their effect on the MOV’scharacteristics. Characteristics given apply s...view more
- Standard45 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 62020-1:2020 applies to residual current monitors for household and similar purposes, having rated operational voltages and a rated voltage of the monitored circuit not exceeding 440 V AC and rated currents not exceeding 125 A.
This first edition cancels and replaces IEC 62020:1998 and IEC 62020:1998/AMD1:2003. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– definition of Type F and Ty...view more
- Standard222 pagesEnglish and French language
sale 15% off
IEC 60282-4:2020 applies to expulsion fuses complying with IEC 60282-2 and specifies additional testing requirements for fuses employing a cutout fuse-base that utilizes polymeric insulators.
- Standard33 pagesEnglish and French language
sale 15% off
IEC 60282-1:2020 applies to all types of high-voltage current-limiting fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated voltages exceeding 1 000 V.
This eighth edition cancels and replaces the seventh edition published in 2009.
This edition includes the following significant technical changes with respect to the previous edition:
– additional information concerning thermally operated strikers;
– the division of ratings, characteristics...view more
- Standard167 pagesEnglish and French language